{"id":1463,"date":"2025-10-08T10:22:29","date_gmt":"2025-10-08T08:22:29","guid":{"rendered":"https:\/\/store.lightcore-technologies.com\/?post_type=product&#038;p=1463"},"modified":"2025-11-24T10:02:35","modified_gmt":"2025-11-24T09:02:35","slug":"ape-picoemerald-ft","status":"publish","type":"product","link":"http:\/\/store.lightcore-technologies.com\/index.php\/product\/ape-picoemerald-ft\/","title":{"rendered":"APE picoEmerald FT"},"content":{"rendered":"<p><strong>picoEmerald FT for Stimulated Raman Microscopy<\/strong><\/p>\n<ul>\n<li>Light source perfectly designed for CARS\/SRS applications<\/li>\n<li>Integrated EOM (20 MHz modulation frequency)<\/li>\n<li>Shot noise limited \u21d2 Extremely low noise compared to all-fiber laser systems<\/li>\n<li>Highly sensitive and fast imaging of: Raman tags, Fingerprint region, CH2-CH3<\/li>\n<li>210 cm-1 \u2026 5450 cm-1 energy difference (Pump to Stokes)<\/li>\n<li>Compatible with commercial microscopes and homebuilt setups<\/li>\n<\/ul>\n<p><strong>Further information on picoEmerald FT for CARS\/SRS Microscopy.<\/strong><br \/>\n<strong>Options<\/strong><\/p>\n<ul>\n<li>Add Idler output: 1055 nm \u2026 2340 nm<\/li>\n<li>Add integrated EOM for SRS applications (20 MHz modulation frequency)<\/li>\n<li>Add APE\u2019s pulseSlicer to narrow output spectrum down to &lt;0.2 cm-1 and elongate pulse duration up to &gt;50 ps<\/li>\n<li>Add APE\u2019s HarmoniXX SHG\/THG to extend the output wavelength range into VIS and UV<\/li>\n<li>Add APE\u2019s pulseSelect for controlled reduction of output repetition rate between single shot and 20 MHz<\/li>\n<\/ul>\n<p><strong>Application Examples Picosecond Laser<\/strong><\/p>\n<ul>\n<li>SRS (Stimulated Raman Scattering) Microscopy<\/li>\n<li>CARS (Coherent Anti-Stokes Raman Scattering) Microscopy<\/li>\n<li>SRP (Stimulated Raman Photothermal) Microscopy<\/li>\n<li>SHG (Second Harmonics Generation) Imaging<\/li>\n<li>Transient Absorption Microscopy (TAM)<\/li>\n<li>Pump-Probe Spectroscopy<\/li>\n<li>Two-Photon Excitation Fluorescence Microscopy<\/li>\n<li>FLIM (Fluorescence Lifetime Imaging Microscopy) \/ FRET (Fluorescence resonance energy transfer)<\/li>\n<li>SEHRS (Surface Enhanced Hyper Raman Spectroscopy)<\/li>\n<li>Quantum Dot Single-Photon and Entangled-Photon Generation<\/li>\n<li>TCSPC (Time Correlated Single Photon Counting)<\/li>\n<li>Ghost Imaging<\/li>\n<\/ul>\n<p><strong>Type of Source<\/strong> : Automated picosecond (narrow-band) tunable light source<br \/>\n<strong>Wavelength 1<\/strong><strong>\u00a01032 nm beam*<\/strong> : 1032 (\u00b1 1.5) nm<br \/>\n<strong>Wavelength 2<\/strong> <strong>OPO Signal :<\/strong> 660 nm &#8230; 1010 nm<br \/>\n<strong>Wavelength 3 OPO Idler*<\/strong>: 1055 nm &#8230; 2340 nm<br \/>\n<strong>Power 1<\/strong> : 1032 nm beam* &gt;700 mW (unmodulated) &gt;350 mW (modulated at 20 MHz)<br \/>\n(customized versions on request)<br \/>\n<strong>Power 2<\/strong> : OPO Signal &gt;600 mW at 800 nm<br \/>\n<strong>Power 3<\/strong> : OPO Idler* &gt;400 mW at 1250 nm<br \/>\n<strong>\u0394\u03bd OPO Signal &#8211; 1032 nm beam*<\/strong>: 210 cm-1 &#8230; 5450 cm-1<br \/>\n<strong>Pulse Width<\/strong> : 2 ps<br \/>\n<strong>Repetition Rate<\/strong> : 40 MHz<br \/>\n<strong>Spectral Bandwidth Signal, 1032 nm beam :<\/strong> 10 cm-1<br \/>\n<strong>Beam Diagnostics :<\/strong> Integrated spectrometer for Signal wavelength and bandwidth<br \/>\nIntegrated sensors for 1032 nm and Signal beam of power, position and temporal overlap<\/p>\n<p><strong>Beam parameters<\/strong><br \/>\n<strong>Pointing Stability<\/strong> : &lt;100 \u03bcrad per 100 nm<br \/>\n<strong>M\u00b2<\/strong>: &lt;1.2 (OPO Signal), typ. 1.2 (1032 nm beam)<br \/>\n<strong>Polarization<\/strong> : Linear; Horizontal &gt;100:1<br \/>\n<strong>Beam Divergence**<\/strong>: 0.8 (\u00b1 0.2) mrad (at 800 nm and 1032 nm)<br \/>\n<strong>Beam Diameter at 2 m after exit**<\/strong>: 3.0 (\u00b1 0.5) mm at 800 nm; 3.2 (\u00b1 0.5) mm at 1032 nm<\/p>\n<p><strong>Software<\/strong><br \/>\n<strong>Software :<\/strong>\u00a0Graphical User interface (GUI) for Windows PC<br \/>\n<strong>Remote Control<\/strong> : Ethernet TCP\/IP \/ Serial RS232<\/p>\n<p><strong>EOM Modulator*<\/strong><br \/>\n<strong>Stokes Modulation<\/strong> : EOM with 20 MHz modulation frequency, exactly half of the repetition rate, built into picoEmerald<\/p>\n<p><strong>Dimensions, Power Consumption, Environment<\/strong><br \/>\n<strong>Dimension :<\/strong><br \/>\npicoEmerald: 962 mm x 318 mm x 472 mm, 104 kg (see drawing for details)<br \/>\nLaser Control Unit: 19 inch (4 U), 11 kg<br \/>\nChiller: 197 mm x 330 mm x 279 mm, 10 kg<br \/>\n<strong>Power :<br \/>\n<\/strong>100 V &#8230; 240 V, 50 Hz &#8230; 60 Hz, max. 450 W (setup without Chiller)<br \/>\n100 V &#8230; 240 V, 50 Hz &#8230; 60 Hz, max. 600 W (Chiller)<br \/>\n<strong>Environmental Conditions :<\/strong> ambient temperature and humidity during operation \/ standby: +18 \u2026 +25\u00b0C, temperature fluctuation: &lt;1\u00b0C recommended, humidity: &lt;60%<\/p>\n<p>*The picoEmerald FT is a modular platform. 1032nm output, EOM and Idler output are optionally available.<\/p>\n<p>**Beam parameters optimized to generate foci with same size and z-position for Pump and Stokes.<\/p>\n<p><a href=\"https:\/\/www.ape-berlin.de\/en\/picosecond-laser-picoemerald-ft\/\">More information.<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>New picosecond light source. 100x faster tuning, 10x faster CARS\/SRS imaging.<\/p>\n<p><strong>Key Features of Tunable Picosecond Laser:<\/strong><\/p>\n<ul>\n<li>One-box, hands-free, shot noise limited<\/li>\n<li>Fast wavelength tuning (100x faster compared to previous model)<\/li>\n<li>Wavelength tuning speed: 1.5 s for a random tuning step<\/li>\n<li>Fully automated and computer controlled<\/li>\n<li>2 ps pulses with 10 cm-1 spectral width<\/li>\n<li>Multi-Color, wavelength tunable outputs<\/li>\n<li>Signal wavelength: 660 nm \u2026 1010 nm<\/li>\n<li>Fundamental: 1032 nm<\/li>\n<li>Idler wavelength (optional): 1055 nm \u2026 2340 nm<\/li>\n<li>Temporal and spatial overlap of Signal and Fundamental beam (Pump and Stokes for CARS\/SRS)<\/li>\n<li>40 MHz pulse repetition rate<\/li>\n<li>Active and passive stabilization, ideal for long-term experiments<\/li>\n<\/ul>\n","protected":false},"featured_media":1508,"template":"","meta":{"_monsterinsights_skip_tracking":false,"_monsterinsights_sitenote_active":false,"_monsterinsights_sitenote_note":"","_monsterinsights_sitenote_category":0},"product_brand":[47],"product_cat":[46],"product_tag":[],"class_list":{"0":"post-1463","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_brand-ape","7":"product_cat-lasers","9":"first","10":"instock","11":"shipping-taxable","12":"product-type-external"},"aioseo_notices":[],"_links":{"self":[{"href":"http:\/\/store.lightcore-technologies.com\/index.php\/wp-json\/wp\/v2\/product\/1463","targetHints":{"allow":["GET"]}}],"collection":[{"href":"http:\/\/store.lightcore-technologies.com\/index.php\/wp-json\/wp\/v2\/product"}],"about":[{"href":"http:\/\/store.lightcore-technologies.com\/index.php\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"http:\/\/store.lightcore-technologies.com\/index.php\/wp-json\/wp\/v2\/media\/1508"}],"wp:attachment":[{"href":"http:\/\/store.lightcore-technologies.com\/index.php\/wp-json\/wp\/v2\/media?parent=1463"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"http:\/\/store.lightcore-technologies.com\/index.php\/wp-json\/wp\/v2\/product_brand?post=1463"},{"taxonomy":"product_cat","embeddable":true,"href":"http:\/\/store.lightcore-technologies.com\/index.php\/wp-json\/wp\/v2\/product_cat?post=1463"},{"taxonomy":"product_tag","embeddable":true,"href":"http:\/\/store.lightcore-technologies.com\/index.php\/wp-json\/wp\/v2\/product_tag?post=1463"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}